commit 6bd115d Author: JieXiong9119 <69597597+JieXiong9119@users.noreply.github.com> Date: Wed Nov 18 13:56:36 2026 -0700 Revert "rubocop auto" This reverts commit f5079bf. commit 93d26c9 Author: JieXiong9119 <69597597+JieXiong9119@users.noreply.github.com> Date: Wed Nov 18 13:56:32 2026 -0700 Revert "fix rubocop introduced bug" This reverts commit d68a5ec.
…missing integration
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Summary
Maps BuildingSync energy recovery ventilators (ERVs) onto L200 topology baselines using ComStock heat recovery. When a recovery record's
VentilationTypeisEnergy recovery ventilator, the baseline workflow overrides heat exchanger effectiveness with ComStock's ERV values.Depends on buildingsync-measures-gem
add-comstock-erv-preset, which adds thecomstock_ervoption tomodify_existing_heat_recovery.Changes
HvacTopologySelector: the recovery match now passes the record'sVentilationTypeinmeasure_argumentsasventilation_type.BaselineHvacPlanner:modify_existing_heat_recoverystep (target_heat_exchanger_names: '*',effectiveness_metric: 'comstock_erv') right after the ComStock recovery step.Integrationis inferred when every linked delivery is central air.Testing
measure_arguments, and the step order for theExample_ASHRAE_L2_Report_l200_erv.xmlfixture.write and run an L200 baseline with ComStock recovery(Example_ASHRAE_L2_Report_l200_erv.xml):heat_exchangers_updatedmatched the number of created loops.baseline/in.osm) has 45 exchangers with ComStock ERV values: sensible 0.675 and latent 0.549 at 100% heating flow.Example_ASHRAE_L2_Report.xml.BuildingEQ-1.0.0.xml.all_measures_applied_example.xml.git diff --checkis clean. RuboCop was not run.Notes / follow-ups